t3.xlarge vs d3en.xlarge
| t3.xlarge | d3en.xlarge |
| General purpose | Storage optimized |
| Websites / web apps, dev environments, build servers, code repositories, microservices, test/staging, and business apps. t – Burstable performance 3 – Generation xlarge – Size | Massively Parallel Processing (MPP) data warehousing, MapReduce/Hadoop computing, distributed/file network systems, and log/data-processing applications. d – Disk / storage optimized 3 – Generation e – Extra storage or memory n – Network and EBS optimized xlarge – Size |
| 4 | 4 |
| 16 GiB | 16 GiB |
| x86_64 | x86_64 |
| Intel Skylake E5 2686 v5 | Intel Xeon Platinum 8259 (Cascade Lake) |
| 2.5 GHz | 3.1 GHz |
| 2 | 2 |
| no | no |
| no | no |
| no | no |
| t3.2xlarge, t3.large, t3.medium, t3.micro, t3.nano, t3.small, t3.xlarge | d3en.12xlarge, d3en.2xlarge, d3en.4xlarge, d3en.6xlarge, d3en.8xlarge, d3en.xlarge |
| t2.xlarge, t3.xlarge | |
| t3a.xlarge | d3.xlarge |
| ml.t3.xlarge | |
| db.t3.xlarge | |
| no | no |
| yes | no |
| yes | no |
| EBS only | 2 x 14000 HDD |
| default | default |
| supported | supported |
| required | required |
| up to 2780 MBps | up to 2800 MBps |
| 695 Mbps | 850 Mbps |
| 86.875 Mbps | 106.25 Mbps |
| 4000 IOPS | 5000 IOPS |
| 15700 IOPS | 15000 IOPS |
| 2780 Mbps | 2800 Mbps |
| 347.5 Mbps | 350 Mbps |
| Up to 5 Gigabit | Up to 25 Gigabit |
| no | yes |
| 4 | 4 |
| 1 | 1 |
| 15 | 3 |
| 15 | 3 |
| yes | yes |
| required | required |
| no | no |
| no | yes |
| no | no |
| 1.00x | 3.25x |
Regional Prices
Geography | Region | t3.xlarge | d3en.xlarge |
|---|---|---|---|
| Europe | Europe (Ireland) (eu-west-1) | n/a | 0.6410 |
| Hidden | Hidden (hidden-1) | 0.1728 | 0.6590 |
| Hidden | Hidden (hidden-10) | 0.1888 | n/a |
| Hidden | Hidden (hidden-11) | 0.1901 | n/a |
| Hidden | Hidden (hidden-12) | 0.1901 | n/a |
| Hidden | Hidden (hidden-13) | 0.1917 | n/a |
| Hidden | Hidden (hidden-14) | 0.1917 | n/a |
| Hidden | Hidden (hidden-15) | 0.1920 | n/a |
| Hidden | Hidden (hidden-16) | 0.1952 | n/a |
| Hidden | Hidden (hidden-17) | 0.1952 | n/a |
| Hidden | Hidden (hidden-18) | 0.1958 | n/a |
| Hidden | Hidden (hidden-19) | 0.1984 | n/a |
| Hidden | Hidden (hidden-2) | 0.1747 | 0.6590 |
| Hidden | Hidden (hidden-20) | 0.2006 | n/a |
| Hidden | Hidden (hidden-21) | 0.2006 | n/a |
| Hidden | Hidden (hidden-22) | 0.2080 | n/a |
| Hidden | Hidden (hidden-23) | 0.2112 | n/a |
| Hidden | Hidden (hidden-24) | 0.2112 | n/a |
| Hidden | Hidden (hidden-25) | 0.2112 | n/a |
| Hidden | Hidden (hidden-26) | 0.2112 | n/a |
| Hidden | Hidden (hidden-27) | 0.2112 | n/a |
| Hidden | Hidden (hidden-28) | 0.2170 | n/a |
| Hidden | Hidden (hidden-29) | 0.2176 | n/a |
| Hidden | Hidden (hidden-3) | 0.1792 | 0.6590 |
| Hidden | Hidden (hidden-30) | 0.2176 | n/a |
| Hidden | Hidden (hidden-31) | 0.2218 | n/a |
| Hidden | Hidden (hidden-32) | 0.2336 | n/a |
| Hidden | Hidden (hidden-33) | 0.2688 | n/a |
| Hidden | Hidden (hidden-4) | 0.1792 | 0.6930 |
| Hidden | Hidden (hidden-5) | 0.1824 | 0.7620 |
| Hidden | Hidden (hidden-6) | 0.1824 | n/a |
| Hidden | Hidden (hidden-7) | 0.1856 | n/a |
| Hidden | Hidden (hidden-8) | 0.1856 | n/a |
| Hidden | Hidden (hidden-9) | 0.1888 | n/a |
| US | US East (Ohio) (us-east-2) | 0.1664 | n/a |
| US | US East (Virginia) (us-east-1) | 0.1664 | 0.5260 |
| US | US West (Oregon) (us-west-2) | 0.1664 | 0.5260 |
Related Comparisons
Other instances worth weighing against these.